二合一熱痛覺測量儀包含足底痛覺測量儀和甩尾測痛儀:
二合一熱痛覺測量儀包含足底痛覺測量儀和甩尾測痛儀
Plantar Test Hargreaves Method 足底痛覺測量儀
Tail Flick Test Analgesia Meter Apparatus 甩尾測痛儀
型號390型+33型 或 390G型+33型
足底痛覺實驗用于測試鎮痛藥物影響無束縛大鼠對外部熱刺激的反應時間使用時先通過從爪下面的測試頭發出導向光將光源移到動物爪底通過反光鏡確定位置避免頻繁彎腰和低頭方便操作啟動加熱光束照射到動物爪底進行實驗。
足底熱測痛儀主要特點
? 精確數字控制 時間精確度為0.01s
? 自動切斷保護功能
? 光束強度可調節步進量1%
? 手工結束測試減少誤觸發
? 強制取消定時器功能
? 數字顯示功能
? 動物不需固定限制
? 加熱玻璃可選配
? 測試頭具有反光鏡輔助觀察
? 標準計算機打印口輸出
? 型號390 爪刺激痛覺測試儀
? 型號390G 爪刺激痛覺測試儀內置熱玻璃
疼痛甩尾測試儀用于測試動物疼痛反應時間和動物對鎮痛藥物的疼痛反應極限。實驗過程中檢測到動物尾部甩動后內置的計時器自動停止計時。
疼痛甩尾測試儀主要特點
? 實時尾部溫度/觸發可選
? 觸發溫度設置功能
? 精確數字控制時間精確度為0.01秒
? 自動切斷保護功能
? 光束強度可調節步進量1%
? 自動檢測活動反應
? 強制取消定時器功能
? 數字顯示功能
? 標準計算機打印口輸出
The IITC Plantar Test Analgesia Meter for paw stimulation can be used on 12 mice, 6 rats and other animals (cats, rabbits) unrestrained when testing for narcotic drugs. Experiments are easy to perform, simply slide the test head under test subject, align the heat source via our exclusive guide light (idle state) by the attached, adjustable, angled mirror on test head to test subject and perform tests.
Start, stop and reset of tests is done by either the push button on test head, front panel controls or supplied footswitch.
With our exclusive “idle state” of the heat source one is assured of exact placement of the heat source. Tests are performed on the plantar surface by a focused, radiant heat light source. The light beam is focused to the top of the glass and creates a 4X6mm intense spot on the paw.
Our method of visible light is superior to the infrared light method, since a user will not always know exactly where/when the test will start, causing false starts and conditioning of animals. A built-in timer displays reaction time in .01 second increments.
The height of the glass is adjustable allowing the focal point of the light to be adjusted to stimulate other body parts if needed. A Humane cutoff timer is standard. The unit can be preset for a cutoff period, at the end of which the heat source shuts off automatically if the animal has not responded, avoiding tissue damage. Our test head does not emit , clicking or whining noises that cause preconditioning of animals prior to test as with other systems on the market.
Our exclusive heated glass option eliminates the glass acting as a heat sink. This feature will eliminate the reaction time of the animals to be altered due to the fact that they are placed on cold glass allowing the possibility of delayed response time to the applied heat source. Built-in heating elements in the glass which are digitally controlled for consistent temperatures. Temperature readout and adjustment from 30-40 degrees c. for the heated base is controlled on the heated base.
Tail Temperature Option Animal enclosure
Three individual, acrylic animal enclosures are supplied. Each enclosure allows for 2 rats/4 mice allowing testing of up to 6 rats/12mice total. Enclsoures have strong magnets to prevent animals from possible escape., individual lids, clear dividers in-between test subjects.
Tail Flick Test mode - the test head is attached to the electronic gear and the heat source now sits over a tail groove that has a sensor that detects the when the animal flicks it tail. System records and displays time and temperature of test. A humane cutoff timer that can be set by user, preventing tail tissue damage if test subject has not reacted within preset time.
TAIL TEMPERATURE OPTION (T)
Measurement of tail temperature at all times.
Trigger temperature is automatic at the start of every test.
This optional feature allows automatic preheating of the tail. To ensure experiment protocols to be precisely controlled and repeated. This feature allows the user to SET the tail temperature at start of each test is to be started at up to 75 degrees Celsius. Once that preset temperature is reached the test and the timer starts automatically and after the tail flicks the timer and light stop and the result is displayed. Readout will now show in repeatable sequence the start and end temperatures as well as test time.
We recommend animals be restrained with one of the IITC restrainers.
This unit solves the problem associated with “tail temperature prior to and at the end of testing.”
See articleKJELL HOLE AND ARNE TJOLSENThe Tail-Flick Formalin Test in RodentsChanges in Skin Temperature as a Confounding Factor.
Pain 53 (1993) pages. 247-254 Elsevier).
Features
Tail Temperature optional (T)
Precise Programmable digital control
Humane cut-off feature, set by user
Adjustable beam intensity in 1% increments
Reaction is detected automatically
(Tail Flick Test set-up)
Manual override of all timer functions
All Functions and parameters entered via key-pad
Heated glass option only from IITC
Footswitch - RS232 - Printer output (standard)
相關文獻
T Schneider, A Roman, A Basta-Kaim, M Kubera… - …, 2008 - Elsevier
… adverse developmental consequences produced by early brain injuries, especially in animal
models of human … valproic acid have not been studied in the presented animal model of autism …
withdrawal test carried out using an Analgesia Meter apparatus (Mod 33, IITC, INC, USA …
R Karlsten, C Post, I Hide, JW Daly - Neuroscience letters, 1991 - Elsevier
… The animals were used only once. Testing of tail flick was performed using an IITC Inc. Model
33 Analgesiameter, with the light focused on the tip of the tail [3]. The intensity of the beam was
adjusted to give a reaction time of 3-4 s before the it injection of the drug solutions …
T Schneider, R Przew?ocki - Neuropsychopharmacology, 2005 -
… The thermal paw withdrawal test was carried out using an Analgesia Meter apparatus (Mod 33,
IITC, Inc., USA) … aberrations described in this paper appear before puberty, which could distinguish the VPA rat model of autism from other animal models of psychiatric …
J Jurcovicova, M Stancikova, K Svik… - Clinical and …, 2001 - clinexprheumatol.org
… They had free access to food. In group four AA was induced and the animals received 60%
of the food consumed by the arthritic rats (group 3) on the previous day … The pain threshold
was measured using the tail flick analgesia meter (Model 33 IITC Inc …
Y Yajima, M Narita, M Narita, N Matsumoto, T Suzuki - Brain research, 2002 - Elsevier
… each of the hind paws of mice was tested individually using a thermal stimulus apparatus (model
33 Analgesia Meter; IITC Inc./Life Science … An aliquot of tissue sample was diluted with an equal volume of electrophoresis sample buffer (Protein Gel Loading Dye-2x …
M Nishiyori, H Ueda - Molecular pain, 2008 -
… 10 μg in the neuropathic pain model, which is consistent with the previous study that … the ICS model is a promising candidate for experimental FMS or generalized pain syndrome models … thermal paw withdrawal test was carried out using a thermal stimulus (Model 33 Tail Flick …
M Kalinichev, KW Easterling, SG Holtzman - Psychopharmacology, 2001 - Springer
… an organism's responsiveness to stress has been exten- sively investigated in several rodent
models … Previous findings by Kehoe and Blass (1986) provide indirect evidence indicating that
maternal … a light source was focused on the lower third of the tail (Model 33, Tail Flick …
K Starowicz, SA Mousa, I Obara, A Chocyk… - Pharmacological …, 2009 - Elsevier
… PWL) in response to noxious thermal stimuli using an Analgesia Meter (mod 33, IITC INC., Landing, NJ … The initial phase of the CCI model of neuropathic pain involves inflammation around the nerve …restricted to the dorsal horns of the spinal cord, similar to previous studies [26 …
AR Gintzler, BR Komisaruk - Brain research, 1991 - Elsevier
… a lamp mounted 8 cm above the tail and was maintained until a response was elicited or 10 s
had elapsed (IITC Inc., Model 33, Landing, NJ) … Since in a previous study, there was no correlation between the magnitude of increase in TFL produced by vaginal stimulation and the …
YZ Gao, SY Guo, QZ Yin, T Hisamitsu… - The American journal of …, 2007 - World Scientific
… Previous studies have demonstrated that electroacupuncture (EA) at ST36 acupoint could produce profound analgesia … recording the tail flick latency (TFL) induced by radiant heat using Model 33 Tail Flick … Briefly, 750 ng of fast recovery sample cRNA were mixed with 750 ng of …
I Pekarkova, S Parara, V Holecek, P Stopka, L Trefil… - Physiol Res, 2001 - med.cas.cz
… It was found in our previous research in the field of pain that after repeated painful … The tail-flick test (TF) (Tail Flick Analgesia Meter Model 33, IITC Inc., Life Science Instruments, USA) measures the … Sample preparation On the last day of the experiment (the 5th day), after all the …
K Niikura, M Narita, M Narita, A Nakamura, D Okutsu… - Neuroscience …, 2008 - Elsevier
… paws of rats were tested individually using a thermal stimulus apparatus (model 33 Analgesia
meter … In the present study, sample preparation was performed 10 days after partial sciatic … 2B).
Consistent with many previous studies which have characterized afferent projections to …
HN Kariuki, TI Kanui, A Yenesew, NB Pa… - 2012 -
… Antinocieptive activity of Toddalia asiatica (L) Lam. in models of central and peripheral pain … Tail flick test A radiant heat tail-flick IITC Inc. Model 33 analgesiometer was used to measure response latencies according to the method described previously (Corrêa et al., 1996) …
*您想獲取產品的資料:
個人信息: